1. Before the dental x ray machine working and testing, you must according with the safety instruction:
Please make sure the machine connect with the power correct, check the equipment work carefully;
Please make sure equipment connect the ground correct;

Please make sure the power supply in dental clinic.



2. In addition, you also must according with the requirements of national special provisions

(for example: Occupational Safety and Accident Prevention Regulations).

Note: During using process, you should make the distance from the focus to skin and some other 

dental equipment in dental clinic as long as possible.



3. The dental equipment placement and storage place should be paid attention to the following:

Please do not use and save in inflammable and explosive places;
Please do not use and save in pressure, temperature, humidity,over the allowed scope environment;
Please do not use and save in the water place;
Please avoid slope instability, vibration and impact (including handling);
Please note that the frequency of the AC power source and allow current and voltage;

Keep well ventilated, avoid direct sunlight.



4. Dental Equipment installation in dentla clinic.

You must according with the technical data to finish all installation tasks.


5. Dental Equipment maintenance
Because the dental equipment include the users operation and diagnosing patients, therefore must be
maintained, checked, diagnosed equipment maintenance every year. And this equipment involved

in high voltage electrical control components, should check the safety of its insulation.



6. Warning:
Dental X-rays are harmful to patients and operators that must comply with safety exposure

factors and operating instructions or wear the Dental X-ray Lead Apron.


7.EMC PERFORMANCE 

Dental X-ray machine may cause electromagnetic interference to other devices by air or by connecting cables.

EMC refers to the ability of the device to suppress the electromagnetic interference of other devices without causing similar electromagnetic interference to other devices. The product design according with YY0505-2012 class 1, type A standard. Comply with the following EMC electromagnetic compatibility radiation and electromagnetic immunity declaration.(see table 1, table 2)